SNF FLOPAM ENTERGY SUBSTATION ACCESS BRIDGE

Plaquemine, Louisiana

Waskey began this project in early 2011, working with the client and engineers from CDI Engineering Solutions. The project required an access bridge spanning a nearby creek to reach an Entergy Substation. Complexities of the job included bridge construction to an exact 55° skew, panel thicknesses in upwards of 19½”, and the precasting of approach slabs and approach foundations. Other interesting features of this project included the use of Waskey’s “Super-Cap,” which measures 2’-6” wide and 2’-10” tall. This capsill was required to fit the projects 18” square piling. Construction was completed by Waskey at both the S. Choctaw Plant and the N. Flannery Plant on time and with the highest standards due to Waskey’s experienced quality control personnel. The panels and capsills were delivered to the project site ready with all materials and necessities for immediate installation.

Project Information

Project Location: Plaquemine, Louisiana

General Contractor: Coastal Bridge Co.

Scope of Work: Access Bridge

87 LF of Precast Bridge Built at 55° Skew

  • 3 – 29’ Spans x 24’ Clear Crowned Bridge
  • 4 – 2’-6” x 2’-10” x 34’-10” Capsills

40 LF of Precast Approaches Built at 55° Skew

  • 2 – 20’ Approach Spans x 24’ Clear Crowned
  • 2 – 5’-0”W x 35’-0”L x 1’-3”TH Foundations

PROJECT STATISTICS

  • Each Span Comprised of 6 Panels, 4 – 5’-0” Wide Interior and 2 – 3’-0” Wide Exterior
    • Interior Panels: 35,000 lbs. – 29’ Spans / 23,200 lbs. – 20’ Spans
      • 8.3 CY – 29’ Spans / 5.5 CY – 20’ Spans of 5000 PSI Concrete
      • 1,475 lbs – 29’ Spans / 1032 lbs – 20’ Spans of Reinforcing Steel
    • Exterior Panels: 23,500 lbs. – 29’ Spans / 16,250 lbs. – 20’ Spans
      • 5.6 CY – 29’ Spans / 3.9 CY – 20’ Spans of 5000 PSI Concrete
      • 824 lbs – 29’ Spans / 657 lbs – 20’ Spans of Reinforcing Steel
  • Each 34’-10” Capsill: 38,500 lbs.
    • 8.98 CY of 5000 PSI Concrete
    • 2,160 LBs. of Reinforcing Steel
  • Each 35’ Approach Foundation: 33,900 lbs.
    • 8.0 CY of 5000 PSI Concrete
    • 1,450 LBs of Reinforcing Steel
  • 250 Lineal Feet of W-Beam Guardrail
  • 150 – 50# Bags of Dayton Sure Grip Grout
Go to top